Head Office Address
JL. Daan Mogot KM.10 No.151, Jakarta Barat, ID

Euro Inverter

Euro Inverter

A unit device that have function to regulate rotation speed of a motor, by changing the frequency. Basic terms principle of an Inverter VFD (Variable Frequency Drive) is to change the input (AC Alternating Current) into DC (Direct Current) and then the output into AC current again with desired frequency so that the motor can be controlled according to the desired speed.

EIS(General Inverter)

  • Input voltage (V) : AC 3PH 400V±15%
  • Input current (A) : Refer to the rated value
  • Input frequency (Hz) :
    50Hz or 60Hz
    Allowed range: 47~63Hz
  • Output voltage (V) : 0~input voltage
  • Output frequency (Hz) : 0~400Hz
  • Control mode : V/F SVC
  • Motor type : Asynchronous motor
  • Speed ratio : Asynchronous motor 1:100
  • Overload capability :
    G type:
    150% of rated current: 1 minute
    180% of rated current: 10 seconds
    200% of rated current: 1 second
    P type:
    120% of rated current: 60 second
  • Frequency setting : Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting, MODBUS communication setting, PROFIBUS communication setting.
    Realize the shifting between the set combination and set channel.
  • Auto voltage adjustment : Keep a stable voltage automatically when the grid voltage transients
  • Fault protection : Provide over 30 fault protection functions: overcurrent, overvoltage,
    undervoltage, overheating, phase loss and overload, etc.
  • Speed tracking : Restart the rotating motor smoothly
  • Terminal analog input resolution: ≤10mV
  • Terminal switch input resolution : ≤ 2ms
  • Analog input : 2 channels (AI1, AI2) 0~10V/0~20mA and 1 channel (AI3) -10~10V
  • Analog output : 2 channels (AO1, AO2) 0~10V /0~20mA
  • Digital input :
    8 channels common input, the Max. frequency: 1kHz
    1 channel high speed input, the Max. frequency: 50kHz
  • Digital output :
    1 channel high speed pulse output, the Max. frequency: 50kHz;
    1 channel Y terminal open collector pole output
  • Relay output :
    2 channels programmable relay output
    RO1A NO, RO1B NC, RO1C common terminal
    RO2A NO, RO2B NC, RO2C common terminal
    Contactor capacity: 3A/250VAC,1A/30VDC
  • Mountable method : Wall, flange and floor mountable
  • Temperature of the running environment : -10~50 , derate above 40C
  • Ingress protection : IP20
  • Cooling : Air-cooling
  • Braking unit :
    Built-in braking unit for below 300G/370P (including 300G/370P)
    Optional External braking unit for others
  • Braking resister : External braking
  • EMC filter :
    Built-in C3 filter
    Optional external filter

 

EIC(Light Duty Economic Inverter)

  • Input voltage (V) :
    1PH 220V (-15%)~240V(+10%)
    3PH 220V(-15%)~240V(+10%)
    3PH 380V (-15%)~440V(+10%)
  • Input current (A) : Refer to the rated value
  • Input frequency (Hz) : 50Hz or 60Hz, allowed range: 47~63Hz
  • Output motor capacity (kW) : Refer to the rated value
  • Output current (A) : Refer to the rated value
  • Output voltage (V) : 0~input voltage, error <5%
  • Output frequency (Hz) : 0~400Hz
  • Control mode : SVPWM, SVC
  • Adjustable-speed ratio : 1:100
  • Speed control accuracy : ±0.2% (SVC)
  • Speed fluctuation : ± 0.3% ( SVC)
  • Torque response : <20ms (SVC)
  • Torque control accuracy : 10%
  • Starting torque : 0. 5Hz/150% ( SVC)
  • Overload capability :
    150% of rated current : 1 minute
    180% of rated current : 10 seconds
    200% of rated current : 1 second
  • Frequency setting method :
    Digital setting, analog setting, pulse frequency setting,
    multi-step speed running setting, simple PLC setting,
    PID setting, MODBUS communication setting.
    Shift between the set combination and set channel.
  • Auto-adjustment of the voltage : Keep a stable voltage automatically when the grid voltage transients
  • Fault protection :
    Provide comprehensive fault protection functions:
    over-current, over-voltage, under-voltage, over-heating, phase loss and overload, etc.
  • Analog input : 1 (AI2) 0~10V/0~20mA and 1 (AI3) -10~10V
  • Analog output : 2 (AO1, AO2) 0~10V/0~20mA
  • Digital input :
    4 common inputs, the Max. frequency : 1 kHz;
    1 high speed input, the Max. frequency : 50kHz
  • Digital output : 1 Y1 terminal output;
  • Relay output :
    2 programmable relay outputs
    RO1A NO, RO1B NC, RO1C common terminal
    RO2A NO, RO2B NC, RO2C common terminal
    Contactor capacity: 3A/AC250V
  • Mountable method : Wall and rail mountable
  • Braking unit : Embedded
  • EMI filter : Optional filter : meet the degree requirement of IEC61800-3 C2, IEC61800-3 C3
  • Temperature of the running environment : -10~50°C Above 40°C, derate 1% for every additional 1°C.
  • Altitude : <1000m Above 1000m, derate 1% for every additional 100m.
  • Protective degree : IP20
  • Cooling : Fan cooling

 

EIA(Heavy Duty Close Loop Vector Control Inverter)

  • Input voltage (V) :
    AC 3PH 380V(-15%)~440V(+10%)
    rated voltage: 380V
  • Input current (A) : Refer to the rated value
  • Inout frequency (Hz) :
    50Hz or 60Hz
    Allowed range: 47~63Hz
  • Output voltage (V) : 0~input voltage
  • Output current (A) : Refer to the rated value
  • Output power (kW) : Refer to the rated value
  • Output frequency (Hz) : 0~400Hz
  • Temperature of the running environment : -10~50degC, if temperature is above 40degC, derate 1% for every additional 1degC.
  • Average non-fault time : 2 years (25degC ambient temperature)
  • Protective degree : IP20
  • Cooling : Air-cooling
  • Braking unit :
    Built-in for inverters of 380V(≤30kW)
    External for others
  • EMC filter :
    Built-in C3 filter for 380V inverters
    No built-in filters for 660V inverters
    External filter:optional